Ensure parameter matches your sensor type (e.g., Pt100 vs. K-type). Temperature overshoots SV System parameters do not match thermal load.
The upper red display shows the current measured temperature.
The lower green display shows the target temperature or active parameter codes. Button Functions
: To set a target temperature, the user presses the SET key, causing the SV display to flash. Using the up and down arrows, the operator dials in the exact degree required before pressing SET again to lock it in. xmtg-2000 temperature controller manual pdf
This section explains how to program the controller, which involves navigating several parameter groups:
In the manual, find parameter M50 . Set this to 1 to enter Manual Mode. In this mode, the PV display shows the temperature, but the SV display shows a percentage of output power (e.g., 50.0 for 50% power). This is invaluable for testing heaters or drying out a system before automation.
| Error Code | Meaning | Solution | |------------|---------|----------| | HHHH | Input open circuit (sensor disconnected) | Check thermocouple or RTD wiring. Replace sensor if broken. | | LLLL | Sensor shorted or below range | Check for shorts. Verify sensor type matches controller setting ( Sn ). | | Er1 | Internal EEPROM error | Reset controller: Remove power for 30 sec. If persists, replace unit. | | --- | PV display flashes | Out of range. Check if temperature exceeds sensor limit. | | PV stays at room temp while heating | Wrong sensor type selected (e.g., K thermocouple set to Pt100) | Enter parameters, locate Sn , and set to correct code (K=0, Pt100=1). | Ensure parameter matches your sensor type (e
The relay output is welded (short circuit) or Ctrl is not set to PID mode.
Features standard PID control with an "Auto-tuning" function, alongside simpler ON/OFF control modes. Output Options:
Typically supports multiple sensor types, including K, E, S, and J-type thermocouples or Pt100 RTDs. Control Modes: The upper red display shows the current measured temperature
Moves the blinking cursor to the digit you want to change. ▲ (Up Arrow): Increases the value of the active digit. ▼ (Down Arrow): Decreases the value of the active digit. 4. Parameter Setup and Programming Guide
Provides a step-by-step for the self-optimization feature, which is the "killer app" of this controller for stabilizing temperature oscillations. Menu Navigation:
Searching for the can be frustrating. Many links lead to sketchy download sites or generic manuals that don't match your specific model revision. This article serves as your ultimate resource—not only helping you locate the genuine PDF but also summarizing its most critical sections so you can get your system running immediately.